IO Bus
IO Bus
IO-Link
SelectionModelsDownloadRequest a quote
IO Bus CIO200-ECIO-4A4B
IO Bus CIO200-ECIO-4A4B
  • Connection Method:
Collection
Request Test
Specifications
Dimensions
Circuit diagram
Accessories
Applications
Customs data
ModelCIO200-ECIO-4A4B
Input polarityPNP
Indicator light -I/OGreen: The channel signal is normal. Red: The port power supply is short-circuited
Indicator light -RUNGreen: OP status; Green slow blinking: SAFEOP status; Green fast blinking: Pre-OP status; Off: Init status
Indicator Light -PWRGreen: The power supply of the module is normal. Red: The power supply of the module is reversed
Number of main station portsUp to 8 ports can be configured
How the master station is connectedM12, 5-core, A-code, female head
Communication rateCOM1:4.8KBps; COM2:38.4KBps; COM3:230.4KBps
Port voltage L+type.24VDC (via US)
Port current L+2A (via US)
Master Station - Slave station communication distance≤20 m
Enter quantity4 way, adaptive
Signal "0" voltage0.3 ~ 5 VDC
Signal "1" voltage12~30VDC
Input currenttype.5mA (via US)
Number of outputs4 way, adaptive
Output port locationX1~X4
Output CurrentSingle channel 2A (via UA)
Port protectionPower supply short circuit protection, power supply port overload protection
Indicator light -LINKGreen: The link is normal; Yellow flash: Link is normal, data communication is normal; Off: The link is not established
Indicator light -ERRBlinking red: A communication error occurs. Off: The module is working properly
Indicator light -IO-LINKGreen: port operation (running) status; Green fast blinking: The port is being connected or an incorrect device is running. Green slow blinking: the port is in the pre-operation state. Green Off: The port is closed
Communication ProtocolEtherCat protocol
Catalogue
CAD Data
Manuals
WhatsApp
+86 18188641602
WhatsApp
(086) 4008856656