Pre-process data directly where it is created
·
8 configurable IO-Link master ports (standard I/O or IO-Link)
Download
Filtering
By product line
By Model
Search filters
You can filter further under this category
Classification
IO-Link Modules(
19
)
Shell Material
Aluminum alloy(
4
)
PA6 + GF(
8
)
Shell color
Metallic silver(
1
)
Black(
8
)
Metallic silver primary color(
3
)
Ptotect degree
IP67 , Epoxy encapsulation(
1
)
IP67, epoxy full potting(
11
)
External dimensions
205mm × 60mm ×34.4mm(
1
)
205mm×60mm×34.4mm(
3
)
155mm×53mm×28.7mm(
4
)
140mm×30mm×24.8mm(
4
)
Weight
515g(
4
)
217g(
4
)
180g(
4
)
Operating temperature
-25℃~70℃(
12
)
Storage/transport temperature
-40℃~85℃(
12
)
Operating humidity
5%~95%(
12
)
Storage/transport humidity
5%~95%(
12
)
Operating atmospheric pressure
80KPa~106KPa(
12
)
Storage/transport atmospheric pressure
80KPa~106KPa(
12
)
I/O port fastening torque
M12:0.5Nm(
12
)
Application environment
Compliant with EN-61131(
1
)
Conforms to EN-61131(
11
)
Vibration testing
Compliant with IEC60068-2(
1
)
Comply with IEC60068-2(
11
)
Shock testing
Compliant with IEC60068-27(
1
)
Comply with IEC60068-27(
11
)
Free fall testing
Compliant with IEC60068-32(
1
)
Comply with IEC60068-32(
11
)
Electromagnetic compatibility (EMC)
Compliant with IEC61000-4-2,-3,-4(
1
)
Comply with IEC61000-4-2,-3,-4(
11
)
Certification
CE,RoHS(
12
)
Installation hole specifications
Φ4.5mm×1;Φ5.5mm×1(
1
)
Φ4.3mm × 4(
4
)
Φ4.5mm×1 ;Φ5.5mm×1(
3
)
Φ4.3mm × 2(
4
)
Connection Method
2 × M12 D-code; 4-pin socket(
1
)
2 × M12 D-code; 4- core hole holder;(
3
)
Physical layer
Ethernet(
1
)
Transmission speed
10/100 Mbps, Full duplex(
4
)
Characteristics
Compliant with protocol specifications(
1
)
Compliant with protocol features(
3
)
Alarm function
Diagnosis alarm, process alarm(
1
)
Diagnostic alarm, process alarm(
3
)
Minimum cycle time
1ms(
4
)
Communication port fastening torque
M12:0.5Nm(
1
)
M12:0.5 Nm(
3
)
Power supply connection method
M12, 5-pin, L-code, male/female(
1
)
M12, 5-core, L-code, male/female head(
3
)
System power supply voltage us
18~30 VDC(type.24VDC)(
1
)
Auxiliary power supply voltage ua
18~30 VDC(type.24VDC)(
1
)
18 to 30 VDC (type.24VDC)(
3
)
Total current Is
12A(
4
)
Total current Ia
12A(
4
)
Static operating current Ic
≤150mA(
4
)
Reverse power protection
Have(
1
)
Power port fastening torque
M12:0.5Nm(
1
)
The number of ports on the master station
Maximum configurable 8 ports(
1
)
Master station connection method
M12, 5-pin, A-code, female(
1
)
IO-Link Version
V1.1.2(
1
)
Communication rate
COM1:4.8KBps;COM2:38.4KBps;COM3:230.4KBps(
1
)
COM1:4.8KBps; COM2:38.4KBps; COM3:230.4KBps(
6
)
Port voltage L+
type.24VDC (via US)(
7
)
Port current L+
2A(via US)(
1
)
2A (via US)(
6
)
Class A
8 ports, X1~X8(
1
)
Master-slave communication distance
≤20m(
1
)
Master-master communication distance
≤100m(
1
)
Number of inputs
8-channel, adaptive(
1
)
Input port location
X1~X8(
1
)
Signal "0" voltage
-0.3~5VDC(
1
)
0.3 ~ 5 VDC(
6
)
Signal "1" voltage
12~30VDC(
7
)
Input current
type.5mA(via US)(
1
)
type.5mA (via US)(
6
)
Number of outputs
8-channel, adaptive(
1
)
8 way, adaptive(
3
)
4 way, adaptive(
3
)
Output port location
X1~X8(
4
)
X1~X4(
3
)
Input polarity
PNP(
13
)
NPN(
6
)
Output Current
Single channel 2A (via UA)(
7
)
Port protection
Power supply short-circuit protection, overload protection for power supply port(
1
)
Power supply short circuit protection, power supply port overload protection(
6
)
PWR
Module power normal;Red: Module power reverse connection(
1
)
I/O
Green: Channel signal normal;Red: Port power short-circuit(
1
)
LINK
Green: Connection normal;Yellow flashing: Connection normal, data communication normal;Off: No connection established(
1
)
IO-LINK
Green: Port operation (running) status;Flashing green quickly: port connection process or wrong device;Flashing green slowly: The port is in pre-operation state;Green off: port is closed(
1
)
Class A(
12
)
Protocol
EtherCat Protocol(
1
)
Maximum load current (actuator)
500 mA(
8
)
Total current UO
< 2.5A(
8
)
Maximum load current (sensor)
200 mA(
8
)
Total current UI
< 1.6A(
8
)
MS
Green: Module status is normal;Green flash: module is not configured;Red: module failure(
1
)
NS
Green: The network status is normal;Green flash: communication not established;Flashing red: communication interrupted(
1
)
Physicallayer
Ethernet(
3
)
SSystem power supply voltage us
18 to 30 VDC (type.24VDC)(
3
)
Power reverse protection
There are(
3
)
Number of main station ports
Up to 8 ports can be configured(
6
)
How the master station is connected
M12, 5-core, A-code, female head(
6
)
Master Station - Slave station communication distance
≤20 m(
6
)
Enter quantity
8 way, adaptive(
3
)
4 way, adaptive(
3
)
Indicator Light -PWR
Green: The power supply of the module is normal. Red: The power supply of the module is reversed(
6
)
Green: The power supply to the module is normal; Off: The power supply to the module is not connected(
2
)
Green: The power supply to the module is normal; Yellow: the auxiliary power supply is not connected(
6
)
Indicator light -I/O
Green: The channel signal is normal. Red: The port power supply is short-circuited(
6
)
Green: The channel signal is normal. Red: The port is faulty(
12
)
Indicator light -LINK
Green: The link is normal; Yellow flash: Link is normal, data communication is normal; Off: The link is not established(
6
)
Indicator light -SF
Red: Module failure(
2
)
Indicator light -BF
Red: Internal error; Red blinking: device name /IP address / The module group status is incorrect(
2
)
Indicator light -IO-LINK
Green: port operation (running) status; Green fast blinking: The port is being connected or an incorrect device is running. Green slow blinking: the port is in the pre-operation state. Green Off: The port is closed(
6
)
Communication Protocol
ProfiNet protocol(
2
)
EtherNet/IP protocol(
2
)
EtherCat protocol(
2
)
Indicator light -MS
Green: The module status is normal; Blinking green: The module is not configured. Red: The module is faulty(
2
)
Indicator light -NS
Green: The network is normal. Blinking green: The communication is not established. Blinking red: The communication is interrupted(
2
)
Indicator light -RUN
Green: OP status; Green slow blinking: SAFEOP status; Green fast blinking: Pre-OP status; Off: Init status(
2
)
Green: The communication is down. Blinking green: The communication is normal. Red: The communication is interrupted(
12
)
Indicator light -ERR
Blinking red: A communication error occurs. Off: The module is working properly(
2
)
Number of IO-Link ports
1 x equipment(
12
)
Minimum cycle
3 ms(
12
)
Number of inputs, outputs
16 inputs(
2
)
16 outputs(
2
)
16 way adaptive(
2
)
8 inputs 8 outputs(
2
)
8 input bytes(
2
)
更多
Rated operating voltage
18~30V DC(
12
)
IO Bus CIO100-M08-DO8N
CIO100-M08-DO8N
Download
Request a Quote
View Details
IO Bus CIO100-M08-DO8P
CIO100-M08-DO8P
Download
Request a Quote
View Details
IO Bus CIO100-M08-DI8N
CIO100-M08-DI8N
Download
Request a Quote
View Details
IO Bus CIO100-M08-DI8P
CIO100-M08-DI8P
Download
Request a Quote
View Details
IO Bus CIO100-M12-DI8DO8N
CIO100-M12-DI8DO8N
Download
Request a Quote
View Details
IO Bus CIO100-M12-DI8DO8P
CIO100-M12-DI8DO8P
Download
Request a Quote
View Details
IO Bus CIO100-M12-DIO16N
CIO100-M12-DIO16N
Download
Request a Quote
View Details
IO Bus CIO100-M12-DIO16P
CIO100-M12-DIO16P
Download
Request a Quote
View Details
IO Bus CIO100-M12-DO16N
CIO100-M12-DO16N
Download
Request a Quote
View Details
IO Bus CIO100-M12-DO16P
CIO100-M12-DO16P
Download
Request a Quote
View Details
IO Bus CIO100-M12-DI16N
CIO100-M12-DI16N
Download
Request a Quote
View Details
IO Bus CIO100-M12-DI16P
CIO100-M12-DI16P
Download
Request a Quote
View Details
IO Bus CIO200-EIIO-4A4B
CIO200-EIIO-4A4B
Download
Request a Quote
View Details
IO Bus CIO200-PNIO-4A4B
CIO200-PNIO-4A4B
Download
Request a Quote
View Details
IO Bus CIO200-ECIO-4A4B
CIO200-ECIO-4A4B
Download
Request a Quote
View Details
IO Bus CIO200-ELLO-8A
CIO200-ELLO-8A
Download
Request a Quote
View Details
IO Bus CIO200-EIIO-8A
CIO200-EIIO-8A
Download
Request a Quote
View Details
IO Bus CIO200-PNIO-8A
CIO200-PNIO-8A
Download
Request a Quote
View Details
IO Bus CIO200-ECIO-8A
CIO200-ECIO-8A
Download
Request a Quote
View Details
Please leave message to get a quotation and solution
Send
Catalogue
CAD Data
Manuals
WhatsApp
+86 18188641602
(086) 4008856656
Akusense Technology Co., Ltd.
#06-06 Nexus@one-north,North tower1Fusionopolis link, Singapore 138542
(086) 4008856656
info@akusense.com
INDUSTRIES
Energy Industry
Semiconductor Industry
Industrial Robots
Electronics Industry
Logistics Industry
Medical Technology
Packaging Industry
Automotive Industry
PRODUCTS
Detection Sensors
Measuring Sensors
Safety
Special Sensors
Vision & Identification
Network & Connection
Accessories
SERVICES
Customize a Sensor
Download Data
Request Test
Express Catalogue
Sensor Training
Compare Products
ABOUT
About US
News
Blogs
Exhibition
Career
Contact US
Certifications
Copyright © 2010-Now AKusense All Rights Reserved
Privacy